MORE than a supplier
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Function | New Codes | Old Descriptors |
|---|---|---|
| Auto reclose & check synch | 7SG117 |
RECLOSER-M |
| Auxiliaries | 7PG11 7PG13 7PG15 7PG17 |
Alpha AR (Aux Relay) MR (Measuring Relay) TR High Speed Tripping XR - Various |
Capacitor bank protection |
7SG23 | MSCDN |
| Communication equipment | 7SG24 | SIGMA converters |
| Distance protection | 7SG16 | Ohmega |
| High impedance protection | 7PG23 7SG12 |
5B3 (Restricted Earth Fault) DAD-N |
| Line differential and phase comparison | 7PG21 7PG2113/4/5/6 7SG18 |
Solkor R/Rf (copper pilot) Guard relays Solkor-N (fibre pilot) |
| Motor protection | 7SG17 | Rho 3 |
| Overcurrent and earth fault protection | 7SG111 7SG112 7SG114 7SG116 7SG117 7SG13 7SR110 & 7SR120 7SR210 & 7SR220 |
Argus1 (O/CE/F) |
| Transformer protection and control | 7SG14 7SG15 7SR242 |
Duobais M MicroTAPP Duobais |
| Voltage and frequency | 7SG118 | Argus 8 |
| Operating programs | Reydisp Evolution Reydisp Manager |
|
| Test blocks | 2RMLG |
Argus-CAfter extensive development, Reyrolle SPD have released a new overcurrent protection relay, perfect for NZ feeder protection applications. The ARGUS-C features:
Protection functions include undervoltage, undercurrent, broken conductor, negative phase sequence, thermal overload, earth fault and sensitive earth fault, CB failure, overvoltage, neutral displacement, high impedance earth fault, directional elements, cold load, CT and VT supervision, trip circuit supervision and lockout.
|
![]() |
Argus-MThe Argus-M is similar to the Argus-C, but significantly offers a larger I/O count and in addition to DNP support, it also offers an IEC 61850 Ethernet interface option. |
![]() |
SolkorThe Solkor R/Rf is a very traditional and reliable approach to differential line protection operating over copper pilot wires. Solkor relays are well known and proven for their simple yet practical protection. Installation is simplified with no need for auxiliary supply circuits. Intertripping and pilot wire supervision products also available. For more complex protection requirements, we recommend the Siemens SIPROTEC 7SD80. |
![]() |
Solkor-NThe Solkor-N is a differential protection relay for use with copper or fibre pilots. It includes pilot supervision, backup over current protection and IEC 103 or MODBUS RTU SCADA interface. |
![]() |
Test blocksThe range of 2RMLG test blocks, housed within an Epsilon enclosure, offers facilities for monitoring and secondary injection testing of power system protection schemes in conjunction with the MMLB 01 multi-fingered test plug. More info on 2RMLG test blocks (PDF, 327 kB) |
Go to Siemens page
Go to SIPROTEC page
Go to REYROLLE website